摘要:研究了离子交换膜在无外加电压的条件下分离去除原水中锰离子的技术,探讨了锰离子浓度、补偿离子钾离子摩尔浓度、水力搅拌速度、温度和水力停留时间(HRT)等对去除效果的影响.实验结果表明,当原水中二价锰离子初始摩尔浓度为0.072 7 mmol/L (即4 mg/L)左右时, 在下述的实验条件下:水温为(25±1) ℃,水力停留时间HRT为6 h,水力搅拌速度为(600±25) r/min,补偿离子钾离子的摩尔浓度是原水中锰离子摩尔浓度的'20倍,锰离子去除率达到80%.此外,在实验装置不改变的条件下,进水锰离子摩尔浓度增加到0.727 mmol/L (即40 mg/L)左右时,去除率会降低到66%;补偿钾离子摩尔浓度与进水锰离子摩尔浓度的比值大于20后,再增加其比值,对去除率影响不大;降低搅拌速度到(300±25) r/min,去除率降低到51%;降低水温到(16±1) ℃,去除率降低到60%;水力停留时间(HRT)大于6 h后,再增加水力停留时间到12 h,去除率无明显改变.Abstract:The removal of manganese ion from water with an ion-exchange membrane under no external voltage condition was studied, and the effects, such as manganese ion concentration, the concentration of compensation potassium ions, water stirring speed, temperature and hydraulic retention time (HRT) on the removal efficiency of manganese ions were also evaluated. The results have shown that, when the initial concentration of bivalent ion Mn~(2+) is 0.0727 mmol/L (4 mg/L), under the experimental conditions of the water temperature of 25 ℃, HRT of 6 h, hydraulic mixing speed of (600±25) r/min, and the concentration of the compensation ion K~+ is 20 times that of Mn~(2+) , the removal efficiency of 80% for the manganese can be achieved. In addition, with the equipments unchanged, when the inlet concentration of manganese increases to 0.727 mmol/L (40 mg/L), the removal efficiency will be lowered to 66%; while the ratio of the concentration of compensation potassium ions to that of inlet manganese is higher than 20, the removal efficiency will not change significantly, if the ratio continues to increase; by lowering the stirring speed to (300±25) r/min, the removal efficiency will be decreased to 51%; by lowering the temperature to (16±1) ℃,the removal efficiency is 60%; when the hydraulic retention time(HRT) is more than 6 h, the removal efficiency will not undergo any significant change by increasing HRT to 12 h. 作者: 谢德华[1]施周[2]陈世洋[2]谢鹏[2]宋勇[2] Author: 作者单位: 湖南大学,土木工程学院,湖南,长沙,410082;湖南科技大学,土木工程学院,湖南,湘潭,411201湖南大学,土木工程学院,湖南,长沙,410082 期 刊: 湖南大学学报(自然科学版)   ISTICEIPKU Journal: JOURNAL OF HUNAN UNIVERSITY(NATURAL SCIENCES) 年,卷(期): 2010, 37(4) 分类号: X505 关键词: 离子交换膜    唐南分离    重金属    锰离子    Keywords: ion exchange membrane    donnan dialysis    heavy metal    manganese    机标分类号: TG1 TH1 机标关键词: 外加电压    离子交换膜    膜分离    除水    锰离子浓度    Application    removal efficiency    摩尔浓度    水力停留时间    hydraulic retention time    去除率    搅拌速度    HRT    钾离子    potassium    water temperature    补偿离子    原水    实验条件    ions 基金项目: 国家自然科学基金资助项目

【无电压作用离子交换膜分离去除水中锰离子的研究】相关文章:

纳米分子筛和硅藻土吸附去除水中锰离子的研究08-01

生物法去除水中重金属离子的研究07-19

离子交换回收电镀废水中六价铬的研究12-29

高锰酸钾和氯气去除水中锰的应用10-11

高锰酸钾和氯气去除水中锰的应用01-10

利用沸石去除电镀废水中重金属离子的试验研究07-19

辉沸石的吸附与离子交换性能的研究08-08

原油对离子交换膜的污染及机理研究10-08

13X分子筛去除水中重金属离子的研究07-19